You are here:

Railway Building

Product advantages :

1. High strength and weight bearing

2. Good insulation

3. Good flame resistant

4. Good aging resistance, no rust

SMC materials for railway building

Recommended  application:

Railway Cable tray,Subway rail cable support, etc.

Typical data  :

Physical propertyTest StandardsUnitsTypical grades and data
FSD-S01-LFSD-S02
Fiberglass contentGB/T

15568-2008
%33%±230%±2
Molding temperature-135 - 145135- 145
Shrink rateGB/T

15568-2008
%≤0.2≤0.2
DensityGB/T

1463-2005
g/cm31.8~1.91.8~1.9
Stretch StrengthGB/T

1447-2005
Mpa≥110≥80
bend StrengthGB/T

1449-2005
Mpa≥200≥180
Bend ModulusGB/T

1449-2005
Gpa≥9≥9
Impact StrengthGB/T

1451-2005
Mpa≥110≥75
Oxygen IndexGB/T

8924-2005
%≥32≥32
Combustion GradeUL-94GradeV0V0

Attention:

1. We can design the color as customers request.

2. We suggest the store environment below 25℃,shade place ,60days .

PropertyFiberglass contentStretch strengthBend strengthImpact strengthShrink rateOxygen indexFlame resistant gradeDielectric strengthArc resistance
Test standardGB/T

15568-2008
GB/T

1447-2005
GB/T

1449-2005
GB/T

1451-2005
GB/T

15568-2008
GB/T

8924-2005
UL-94GB/T

1408-2006
GB/T

1411-2002
Unit%Map

MapKJ/㎡%%GradeKV/mmGB/T

1411-2002
B-0120%±2≥45≥135≥40≤0.15≥28V1≥12≥180
B-0225%±2≥55≥155≥50≤0.15≥28V1≥12≥180
D-0120%±2≥45≥135

≥40≤0.15≥32V0≥12≥180
D-0224%±2≥50≥155

≥50≤0.15≥32V0≥12≥180
D-0326%±2≥60≥160≥55≤0.15≥32V0≥12≥180
Thermal deformation temperatureGB/T

1634.1-2004
≥200≥200≥200≥200